<LOGO>
FM Transmitter Measurement Report
Created: 2025-12-14 11-10-18
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.60 MHz 5/5, 66 dBuV P3 SR
Pilot RDS Phase Difference
5.7 kHz 3.1 kHz 3 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
16 kHz 121 kHz 18919 13,0451
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-3,8 dBr -1,99 dBr -0,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"P3 SR " E203 12 (Easy M) 0 1 1 9 10:10, 14.12.2025
RT
"Morgonpasset i P3 med Branne Pavlovic och Matilda RĂ¥nge "
AF EON
97.9, 99.0, 99.4, 100.5 MHz E201, E402, E224
FM Scope Max at: 121 kHz MIN: 16 kHz % above 76 kHz: 13,0451 Acquired: 2025/12/14 11.09.13 Total samples: 18919 Equivalent time: 0:15:45 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: -0,9 dBr MIN: -3,8 dBr AVE: -1,99 dBr % above 12,2 dBr: 0,0 Last value: -2,4 dBr (2025/12/14 11.09.12) 10.56 10.58 11.00 11.02 11.04 11.06 11.08 -4 -3 -2 -1 0 1 Pm [dBr]